Scantronic:
1090 Twintec® Indoor Glass Breakage Detector
The
Twintec Dual Audio Analyser is a two stage glass break detector
which examines the low frequency and high frequency sounds generated
by breaking glass. The Dual Audio Analyser is designed for proetection
of large, small or multiple pane windows containing glass from 3mm
to 12mm thickness. The Dual Audio Analyser however, is not suitable
for protecting wired, tempered or laminated glass.
Type
Domestic and commercial Twintec indoor glass breakage detector
Coverage
Protects
a 9 metre range of glass thickness between 2mm and 12mm
Detection
analysis
Circuitry designed to analyse two predictable sounds at
precisely timed intervals. These specific audio components must
occur in the right order in the right time frames. One without the
other, or the appearance in the wrong order produces no response.
Circuitry
Very
high immunity to audio and radio frequency interference.
Field
Adjustments
Requires
no field adjustments, all the setting s are factory calibrated under
laboratory conditions.
Mounting
Options
Wall
mounted or ceiling mounted
Current
Consumption (Quiescent)
30mA
Voltage
Range
10.5V
- 15V
Dimensions
(HxWxD)mm
135
x 67 x 26
Warranty
5
years. |